The first Agreement certificate issued
for an entire product series: the PARALON range rather than a single
product. |
|
The first Agreement certificate covering fire resistant
roofing products. |
|
The first Agreement certificate covering products
with different types of reinforcement: classic continuous filament
polyester fabric, stabilized continuous filament polyester fabric,
and composite. |
|
The first Agreement certificate covering both 3
mm and 4 mm thick versions. |
The
new ITC Agreement certificate confirms the outstanding technical merits
that have made PARALON a byword for reliable performance and durability
for over 25 years. ITC - the Italian National Research Council’s
Institute of Construction Technologies - has extended European Technical
Approval certification to the entire PARALON range of products designed
to meet the most widely varying design and application needs. Certification
covers both talc-treated and slate surfaced membranes, as well as those
featuring the innovative TEXTENE® finish.
PARALON NT4 PLUS
Elasto-plastomeric bitumen polymer membrane with non-woven continuous
filament polyester fabric reinforcing mat.
Thickness: 4 mm
Cold flexibility: -20 °C
Optional TEXTENE® finish on upper face may be specified instead of
standard talc
treatment.
PARALON
ARD/HS PLUS
Elasto-plastomeric bitumen polymer membrane with non-woven continuous
filament polyester fabric reinforcing mat. Upper face surfaced with slate
chipping's.
Available in red, green and natural slate grey.
Thickness: 4 mm (plus slate chipping's)
Cold flexibility: -20 °C
PARALON ARD/S PLUS
Elasto-plastomeric bitumen polymer membrane with non-woven continuous
filament polyester fabric reinforcing mat. Upper face surfaced with slate
chipping's.
Available in red, charcoal and natural slate grey.
Mass: 4.5 kg/m2
Cold flexibility: -20 °C
| Compound |
|
|
PARALLOY ®
(high performance elasto-plastomeric) |
| Reinforcement |
|
|
Continuous filament
polyester |
Stabilized continuous
filament polyester |
| Roll dimensions |
EN 1848-1 |
m |
1 x 8 |
1 x 8 |
1 x 8 |
1 x 8 |
1 x 8 |
| Thickness |
EN 1849-1 |
mm |
4 |
|
4 + Slate |
4 |
4 + Slate |
| Mass |
EN 1849-1 |
kg/m2 |
|
4,5 |
|
|
|
| Standard colour |
|
- |
Black |
Grey 2) |
Grey 2) |
Black |
Grey 2) |
Tensile strength (maximum load
= breaking load) |
EN 12311-1 |
|
|
|
|
|
|
| - Strength (L/T) |
|
N/5 cm |
750/650 |
750/650 |
750/650 |
750/650 |
750/650 |
| - Elongation (L/T) |
|
% |
50/50 |
50/50 |
50/50 |
50/50 |
50/50 |
| Cold flexibility |
EN 1109 |
°C |
-20 |
-20 |
-20 |
-20 |
-20 |
Puncture resistance
Static indentation |
EN 12730 |
Class L |
L25 |
L25 |
L25 |
L25 |
L25 |
Puncture resistance
Dynamic indentation |
EN 12691 |
Class I |
I10 |
I10 |
I10 |
I10 |
I10 |
Shape stability at 140 °C
|
EN 1110 |
- |
|
|
|
|
|
| Water impermeability at 60 kPa |
EN 1928 |
- |
|
|
|
|
|
| Dimensional stability, L/T |
EN 1107-1/A |
% |
< 0,5/0,5 |
< 0,5/0,5 |
< 0,5/0,5 |
< 0,5/0,5 |
< 0,5/0,5 |
| Tear resistance, L/T |
EN 12310-1 |
N |
160/180 |
160/180 |
160/180 |
160/180 |
160/180 |
Heat aging in air
- Cold flexibility after heating
- for 180 days at 70 °C |
EN 1109 |
°C |
-15 |
-15 |
-15 |
-15 |
-15 |
Q.U.V. Accelerated
Weathering Tester exposure.
Test cycle:
- 4 hours of UV ASTM/ Passes test
radiation, peak emission ANSI G 53
313 nm at 60 °C
- 4 hours of vapor
condensation at 40 °C
Test duration : 400 hours |
ASTM/
ANSI G 53 |
Passes
test |
1) If not otherwise specified, stated
values are subject to the tolerances envisaged by UEAtc Directives for
bitumen-polymer elastomer membranes.
2) Also available in green and red. Slate colours may vary according to
chip orientation or as a result of normal shading tolerances.
3) UBAtc - ATG 1364 certification (following tests LMC No. E/61038 and
5/61039 on PARALON NT4 PLUS FIRE and PARALON ARD/HS PLUS FIRE).
4) CSI/0116/94/RF certification (following tests CSE RF 2/75/4 and CSE