The roofing system was designed by Imper Roof Ltd. in consultation
with Murray & Dunlop Architects 1 Hill Street Glasgow
Existing roof coverings
2 layers mastic asphalt
Sheathing felt isolating layer over concrete roofing deck
SPECIFICATION
Primer
Apply one coat IMPER primer to total roof areas,
upstands and copes.
Vapour control Layer
Torch bond one layer IMPER Paralon 77 3mm. vapour controls
layer to primed asphalt.
Insulation "U" value 0.45.
55mm. IMPER TORCHTHANE 40/15 PUR/Pertile factory laminate
bonded to Vapour control layer with IMPER PU Adhesive.
Underlayer
Torch bond one layer IMPER Paralon 77 3mm. underlay
to insulation board. (100mm. side laps, 150mm. end laps.)
Cap Sheet
Torch bond layer IMPER Paralon ARD/HS PLUS Mineral
Surface Cap Sheet to underlay. (100mm. side laps, 150mm. ends laps).
The above roofing contract was carried out by George Brolly
(Roofing) Ltd Peel Lane Glasgow, and is supported by a 20 year Guarantee
on materials and workmanship.
<< Back to